What was found
RT AFT EXTERIOR EMERGENCY LIGHT INOPERATIVE, FOUND EMERGENCY LIGHT CONNECTOR, DISCONNECTED BEHIND SIDEWALL, 272MRW, FOR RT EXTERIOR LIGHT NR 6. RECONNECTED AND PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 33-51-15. OPS TEST GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT AFT EXTERIOR EMERGENCY LIGHT INOPERATIVE, FOUND EMERGENCY LIGHT CONNECTOR, DISCONNECTED BEHIND SIDEWALL, 272MRW, FOR RT EXTERIOR LIGHT NR 6. RECONNECTED AND PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 33-51-15. OPS TEST GOOD.