What was found
FS 280 FLOORBEAM ANGLE AT LBL 5 HAS DRILL SPOT ABOVE THE FASTENER HOLE DEEP 0.030 AND .300 LONG AND THE ANGLE HAS DOUBLER HOLE. REPAIRED IAW EA CRJ953-04653.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280 FLOORBEAM ANGLE AT LBL 5 HAS DRILL SPOT ABOVE THE FASTENER HOLE DEEP 0.030 AND .300 LONG AND THE ANGLE HAS DOUBLER HOLE. REPAIRED IAW EA CRJ953-04653.