What was found
FRAME IS CORRODED AT FS 265 BETWEEN STR 26R TO 26L. UPON INVESTIGATION, FOUND NO CORROSION TO FS 265 FRAME, CORROSION LIMITED TO STIFFENING ANGLE. R & R STIFFENING ANGLE IAW SRM 51-40-11-001-001-A01 & 51-42-06-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME IS CORRODED AT FS 265 BETWEEN STR 26R TO 26L. UPON INVESTIGATION, FOUND NO CORROSION TO FS 265 FRAME, CORROSION LIMITED TO STIFFENING ANGLE. R & R STIFFENING ANGLE IAW SRM 51-40-11-001-001-A01 & 51-42-06-001-001-A01.