What was found
SERVICE DOOR LOWER SILL STRIKER IS CORRODED ALONG ENTIRE LENGTH AROUND FASTENER HOLES. REMOVED AND REPLACED THE STRIKER IAW SRM 51-4-11-001-001-A01 AND 51-42-06-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR LOWER SILL STRIKER IS CORRODED ALONG ENTIRE LENGTH AROUND FASTENER HOLES. REMOVED AND REPLACED THE STRIKER IAW SRM 51-4-11-001-001-A01 AND 51-42-06-001-001-A01.