What was found
EMERGENCY LIGHTED FLOOR LEVEL SIGN ON LEFT SIDE PAX ENTRANCE ON BULKHEAD FOUND INOP. UPON FURTHER INSPECTION FOUND BROKEN WIRE FWD OF BULKHEAD WHERE JUMPSEAT IS STOWED, REQUIRES NEW PIN AND REINSTALLED INTO SPLICE LOCATION. FOUND WIRE REMOVED FROM CONNECTOR ON AIRFRAME SIDE. CUT SERVICEABLE SECTION OF WIRE WITH CONNECTOR OFF SERVICEABLE LIGHTED ASSY P/N 6020-6 AND SPLICED TO BROKEN WIRE IAW ESPM 20-16-00. OPS TEST EMERGENCY LIGHTS GOOD IAW AMM 33-51-00 AT THIS TIME.