What was found
GEAR DISAGREE WARNING ON FINAL. NOSE GEAR DID NOT SHOW DOWN & LOCKED. PERFORMED QRH & NOSE GEAR SHOWED DOWN. DID NOT CYCLE THE GEAR LEVER. PERFORMED A FUNCTION TEST OF EXTENSION & RETRACTION SYSTEM IAW AMM 32-50-00, CHECKED NORMAL CHECKED NLG DOWN LOCK PROXIMITY SENSOR FOR CONDITION AND CLEARANCE IAW AMM 32-61-05. CLEARANCE GOOD. VERIFIED CHECK VALVES ON BOTH BRAKE CONTROL VALVE WERE INSTALLED PROPERLY IAW AMM 32-43-06. BLED HYD SYS IAW AMM 12-13-29. PERFORMED MULTIPLE EXTENSIONS AND RETRACTIONS OF LANDING GEAR IAW AMM 32-30-00. OPS TESTED NORMAL.