What was found
MAIN ENTRANCE DOOR, FWD SIDE LOWER STAIR ACCESS PANEL FRAME AREA WAS CORRODED. REMOVED & REPLACED THE FWD SIDE RISER WEB IAW SRM 51-42-06, AND 51-42-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN ENTRANCE DOOR, FWD SIDE LOWER STAIR ACCESS PANEL FRAME AREA WAS CORRODED. REMOVED & REPLACED THE FWD SIDE RISER WEB IAW SRM 51-42-06, AND 51-42-13.