Service difficulty report · Duct · Cndair CL6002B19

Difficulty date
August 27, 2018
Submitted
August 28, 2018
Operation
Air carrier
Aircraft
N800AY
Make and model
Cndair CL6002B19
Aircraft serial
8000
Aircraft time
27,852 hours, 25,514 cycles
Part
Duct
Condition
Displaced
Location
Anti-Ice Supply
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT 14TH DUCT WARNING MESSAGE. QRH COMPLETED. MESSAGE PERSISTED AFTER 40 SECONDS. RIGHT THRUST LEVER REDUCED TO IDLE. LANDING AT FLAPS 20, ON TOUCHDOWN. FOUND THE RT ENGINE COWL ICE, 14TH STG SUPPLY DUCT CLAMP ALIGNMENT OFF. INSTALLED THE SEAL, ALIGNED THE DUCT & SECURED THE CLAMP. PERFORMED A GROUND RUN, OPS & LEAK CHECKED GOOD. COMPLIED WITH AMM 71-00-00-4.