As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INITIAL INSPECTION. CORROSION ON STRINGER SPLICE (5EAS) BTW FS 329-339 AND STR 25L-25R AT MAIN AVIONICS COMPARTMENT.(SM)(E/E)(TCI 100-09) COMPLETE: SUMMARY: NEW JOINT PIECE STRINGER (5EA) WERE INSTALLED PER SRM 51-42-06-001-001-A01 AND 51-42-20-001-001-A01. LEVEL CORROSION 2.