What was found
RH WING 311TH FUEL PANEL FROM O/B PANEL LAND HAS CORROSION ON I/B SIDE. R/H WING LWR SKIN PLANK @ FUEL ACCESS CUTOUT 640BB REPAIRED, RESTORED FINISH, TREATED, MAX MAT IN LIMIT LK CK C/WR/H WING LWR SKIN PLANK @ FUEL ACCESS CUTOUT 640DB REPAIRED, RESTORED FINISH, TREATED, MAX MATERIAL LOSS FOUND TO BE WITHIN LIMITS BOND CHECK GOOD, IAW BOMBARDIER REO 601R-57-21-030 REV L LEAK CHECK C/W ON W/O 1016231-6000-0002 S/N 6587076 BLOCK 2 AAR SM-107