What was found
FLOOR ANGLE STRIP ON THE FWD SIDE OF BEAM 280 IS CRACKED IN 2 SPOTS, JUST I/B OF LBL 9 AND RBL 9, IN THE VERY FWD E & E BAY. REMOVED AND REPLACED FLOOR ANGLE IAW CRJ 200 SRM 51-42-21 AAR SM-107
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR ANGLE STRIP ON THE FWD SIDE OF BEAM 280 IS CRACKED IN 2 SPOTS, JUST I/B OF LBL 9 AND RBL 9, IN THE VERY FWD E & E BAY. REMOVED AND REPLACED FLOOR ANGLE IAW CRJ 200 SRM 51-42-21 AAR SM-107