What was found
EMERG LIGHTS INOP. PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTS IAW AMM 33-51-17. OPS CHECK FAIL. R&R BATTERY PACKS IAW JOBCARD 33-900-701. BATTERY PACK POSTIIONS R&R PS38, PS37, PS36, + PS35. A/C OK FOR SVC. OPS CHK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERG LIGHTS INOP. PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTS IAW AMM 33-51-17. OPS CHECK FAIL. R&R BATTERY PACKS IAW JOBCARD 33-900-701. BATTERY PACK POSTIIONS R&R PS38, PS37, PS36, + PS35. A/C OK FOR SVC. OPS CHK GOOD.