What was found
DURING COMPLIANCE OF SDI RPB FWD FACE (TC 53-280-607) NOTED RPB SUSTAINED 5 LINER HARDWARE STRIKES @ LBL27.5, 18,+ RBL 18,27.5,36.2 ALL IN A LINE HORIZONTAL. APPROX 29.75". ALSO NOTED 5 RIVIT HEAD STRIKES @LBL 36.2,27.5,18 + RBL 27.5, 36.2. ALL IN A LINE HORIZONTAL APPROX 13" UP BLENDED OUT SURFACE DAMAGE ON AFT BULK HEAD WEB IAW BOMBARDIER REV #A 601R-53-61-2155. REPLACED DAMAGE RIVITS IAW CRJ 200 SRM 51-42-06. SEE CONTINUATION CARD #114971 FOR DETAILS