As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INITIAL INSPECTION: CORROSION ON LIGHT CLIP SUPPORT ASSY IN STA. FS= 959 BETWEEN STR 23R TO 24R AT AFT LAVATORY SERVICE PANELS. (FUS) (TCI: 100-19) SUMMARY IN REFERENCE 292; LEVEL CORROSION 2; LIGHT CLIP SUPPORT ASSY IN STA. FS= 959 BETWEEN STR 23R TO 24R WAS REPLACED PER SRM 51-42-02-001-001-A01 PAR. 5.