What was found
DURING FA CABIN PRE-FLIGHT, SHE FOUND THE CABIN EMERGENCY LIGHT-FLOOR LEVEL LIGHTED EXIT SIGN IN THE GALLEY BY THE SERVICE DOOR INOPERATIVE. DEFERRED CABIN EMERGENCY LIGHTS PER MEL 33-51-1A CAT "A" ENTERED IN MM02 PLACARD APPLIED MC 96579 NOTIFIED*******REMOVED & REPLACED GALLEY EMERGENCY FLOOR LIGHT & RE-SECURED GROUND WIRE IAW AMM 33-51-19, OPS CHECK GOOD. MM02 UPDATED, PLACARD REMOVED. MOC NOTIFIED #96183