What was found
INITIAL INSPECTION: CORROSION ON STR SPLICE BTW FS=349.00 / FS=319.00 AND STR 26L / STGR 24R AT INTERNAL STRUCTURE OF MAIN AVIONICS COMPARTMENT (E/E) (SM). IN REFERENCE NRC 00026 TASK 900-53-140-300 APPENDIX A ]. SUMMARY:STR SPLICE BTW FS=349.00 / FS=319.00 STR 26L, STR 27 AND 24R AT INTERNAL STRUCTURE OF MAIN AVIONICS COMPARTMENT (E/E) (SM). WERE CLEANED PER SRM 51-26-00-001-001-A01 PAR. 3. C. AREA WAS RE-INSPECTED ON SPLICE STR 26L, SPLICE STR 27 AND SPLICE STR 24R BTW FS=349.00 / FS=319.00 AT INTERNAL STRUCTURE OF MAIN AVIONICS COMPARTMENT AND NOT WAS FOUND CORROSION PER NDTM 51-20-009-210 CONFIG.A01. STR SPLICE BTW FS=349.00 / FS=319.00 STR 26R AND STR 25R AT INTERNAL STRUCTURE OF MAIN AVIONICS COMPARTMENT (E/E) (SM) WERE REPLACED PER SRM 51-42-21-001-001-A01 AND 51-42-06-001-001-A01.