What was found
AWR: CORROSION ON FLOOR FITTING SUPPORT BTW FS=280/295 AND RBL 38 IN REF R53520 STEP 7 (SM)[W1]. SUMMARY OF NRC 231 CORROSION LEVEL 2: FLOOR FITTING SUPPORT BTW FS=280/295 AND RBL 38 WAS REPLACED PER CRJ-900 SRM 51-42-20-001-001-A01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AWR: CORROSION ON FLOOR FITTING SUPPORT BTW FS=280/295 AND RBL 38 IN REF R53520 STEP 7 (SM)[W1]. SUMMARY OF NRC 231 CORROSION LEVEL 2: FLOOR FITTING SUPPORT BTW FS=280/295 AND RBL 38 WAS REPLACED PER CRJ-900 SRM 51-42-20-001-001-A01