What was found
L/H WING DRY BAY ACCESS PANEL 540BT LANDING HAS CORROSION. REMOVED CORROSION I.A.W. CRJ-200 SRM 51-21-06 AND FOUND TO BE WITHIN LIMITS I.A.W. DRAWING TOLERANCE DWG NO. 601R10042 VIEW P SHEET 2 ( .202" MIN REMAINING- DWG TOLERANCE .195"-.205" ).