What was found
FLOOR BEAM SUPPORT ANGLE CRACKED AT FS280.00 LBL9 OTBD. REMOVED CRACKED FLOOR BEAM SUPPORT ANGLE AT F.S. 280, LBL 9 OTBD. FABRICATED AND INSTALLED NEW ANGLE I.A.W. CRJ-200 SRM 51-24-16, SRM 51-24-36, SRM 51-42-21 AND TR 51-42.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM SUPPORT ANGLE CRACKED AT FS280.00 LBL9 OTBD. REMOVED CRACKED FLOOR BEAM SUPPORT ANGLE AT F.S. 280, LBL 9 OTBD. FABRICATED AND INSTALLED NEW ANGLE I.A.W. CRJ-200 SRM 51-24-16, SRM 51-24-36, SRM 51-42-21 AND TR 51-42.