What was found
FLOOR BEAM LBL 9 O/B PANEL LANDING HAS CORROSION SPOTS BETWEEN FS 574 THRU FS 621, IN THE CARGO BAY. REMOVED AND REPLACED FLOOR BEAM CAP IAW CRJ 200 SRM 51-42-21 51-42-2 AAR SM 17
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM LBL 9 O/B PANEL LANDING HAS CORROSION SPOTS BETWEEN FS 574 THRU FS 621, IN THE CARGO BAY. REMOVED AND REPLACED FLOOR BEAM CAP IAW CRJ 200 SRM 51-42-21 51-42-2 AAR SM 17