What was found
"INITIAL INSPECTION: CORROSION ON FLOOR PANEL SUPPORT ANGLE OF ACCESS P ANEL 221ALF IN STA. FS= 280 BETWEEN 11 LBL/RBL AT COCKPIT. (CPIL) TCI 53-10-219 " "SUMMARY: AREA WAS MEASURED AND FOUND WITH DIMENSIONS AS FOLLOW; ORIGIN AL THICKNESS: 0.063"" MAXIMUM DEPTH: 0.025"" THEREFORE IS OUT LIMITS PER CRJ/900 SRM 53-00-00-101-001-A01 PAR. 4 A. IT MUST BE REPLACED PER CR J900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01. // USED EQUIPMENT: DIAL INDICATOR P/N: 543-783 DATE EXP. 16/JUL/19 N/C:23 80 RCG FLOOR PANEL SUPPORT ANGLE OF ACCESS PANEL 221ALF IN STA. FS= 28 0 BETWEEN 11 LBL/RBL AT COCKPIT. WAS REPLACED PER CRJ900 SRM 51-42-06- 001-001-A01 PAR. 6. D. AND CRJ900 SRM 51-42-21-001-001-A01. PAR. 6
"