Service difficulty report · Lamp · Cndair CL6002D24

Difficulty date
June 6, 2019
Submitted
June 17, 2019
Operation
Air carrier
Aircraft
N676CA
Make and model
Cndair CL6002D24
Aircraft serial
15127
Aircraft time
28,299 hours, 18,759 cycles
Part
Lamp
Part number
3071BPEGPL
Condition
Inoperative
Location
Emergency Light
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING THE FA'S PREFLIGHT INSPECTION, IT WAS OBSERVED THAT THE EMERGECNY EXIT SIGN IN ROW 12CD HAD A BURNT-OUT LIGHT BULB. DEFERRED RIGHT SIDE EMERGENCY LIGHT STRIP AT ROW 12CD IAW MEL 33-51-1F. PLACARD INSTALLED, MOC NOTIFIED 97766. (25% LIGHTING INOPERATIVE). RELAMPED FLOOR LEVEL LIGHTED EMERGENCY EXIT SIGN AT 12CD IAW CRJ 900 33-51-11(AMM). OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.