What was found
FS 280 FLOOR SUPPORT BEAM PREVIOUS REPAIR CLIPS CRACKED INBD AND OB. LOCATED, DRILLED, AND INSTALLED I/B AND O/B FS 280.00 CLIPS PN 601R3113-57 AT LBL 9.0 IAW CRJ 200 SRM 51-42-21, 51-40-11, TR 51-42 AND RE-MOVED TAPE. WVAC 712
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280 FLOOR SUPPORT BEAM PREVIOUS REPAIR CLIPS CRACKED INBD AND OB. LOCATED, DRILLED, AND INSTALLED I/B AND O/B FS 280.00 CLIPS PN 601R3113-57 AT LBL 9.0 IAW CRJ 200 SRM 51-42-21, 51-40-11, TR 51-42 AND RE-MOVED TAPE. WVAC 712