What was found
AFTER BUSHINGS REMOVAL CORROSION ON HOUSING OF FITTINGS WAS FOUND AT NLG WHELL WELL (FYT). FITTINGS AT NLG WHELL WELL WERE REPLACED PER CRJ-900 SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER BUSHINGS REMOVAL CORROSION ON HOUSING OF FITTINGS WAS FOUND AT NLG WHELL WELL (FYT). FITTINGS AT NLG WHELL WELL WERE REPLACED PER CRJ-900 SRM 51-42-21.