What was found
"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) " "CORROSION LEVEL 1. CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA WAS REMOVED PER CRJ 900 SRM 51-21-06-001-A01 PAR 5 D AND AREA WAS MEASURED AND FOUND WHIT FOLLOWING DIMENCSIONS: OT:0.063"" AND RT:0.058"" THEREFORE IS WITHIN LIMITS PER CRJ-900 SRM 53-21-23-101-001-A0
"