What was found
AC GROUND POWER SUBSTRUCTURE CRACKED AT FWD/UPPER FASTENER REMOVED & REPLACED GROUND POWER SUPPORT MEMBER BRACKET IAW SRM 51-40-11 & 51-42-06. OPS TEST GOOD IAW CRJ 200 AMM 24-24-01-710-801. WVAC EMP 750 STAMP
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AC GROUND POWER SUBSTRUCTURE CRACKED AT FWD/UPPER FASTENER REMOVED & REPLACED GROUND POWER SUPPORT MEMBER BRACKET IAW SRM 51-40-11 & 51-42-06. OPS TEST GOOD IAW CRJ 200 AMM 24-24-01-710-801. WVAC EMP 750 STAMP