What was found
"INITIAL INSPECTION: PREVIOUS TOOL MARK ON SKIN (INNER FACE) IN STA. FSL 36.00 FLS TO FSL 42.00 (AD)(BORESCOPE) ""PREVIOUS TOOL MARK ON SKIN (INNER FACE) IN STA. FSL 36.00 FLS TO FSL 42.00 WAS BLENDED OUT PER CRJ900 SRM 51-12-00-001-001-A01 PAR. . 5.B.2. AREA WAS MEASURED AND FOUND WITH THE FOLLOWING DIMENSIONS DEPTH=0.002"" ORIGINAL THICKNESS IS 0.063"" THEREFORE ITS WITHIN ON LIMITS PER CRJ--900 SRM 57-52-01-101-001-A01 PAR. 3. AND PREVIOUS REIPAR WAS REPLACED PER CRJ/900 SRM 57-52-01-201-001-A01 PAR 4D AND CRJ900 SRM 51-42-10-001-001-A01 PAR 8
"