What was found
"INITIAL INSPECTION: DELAMINATED FLOOR PANEL 252DRF AT PAX CABIN. " "SUMMARY: FLOOR PANEL 252DRF AT AFT BAGGAGE BAY ARE OUT OF LIMITS WITH DIMENSION 149IN^2 PER CRJ 900 CMM ATA 53 COMCMM-030 REV. T PAR. 8.0 THEREFORE WAS REPLACED PER CRJ900 AMM 53-00-47-400-802. A14 "