What was found
AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON MID CAP ANGLE IN STA. FS= 310 TO FS= 349 AND 41LBL AT MAIN ENTRANCE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
CORROSION LEVEL 2. MID CAP ANGLE IN STA. FS= 310 TO FS= 349 AND 41LBL AT MAIN ENTRANCE DOOR LOWER SILL, FWD WET AREA WAS REPLACED PER CRJ/900 SRM 51-41-02-001-001-A01 PAR 6A