What was found
FOUND EMERGENCY EXIT LIGHTS AT SERVICE DOOR (DS11LY), PAX DOOR (DS10LY), AND FLOOR TRACK LIGHTING LAMP 1 (DS12LY) INOPS WHILE T/S FOUND BROKEN WIRE AT FLOOR PROXIMITY EXIT SIGN PASSENGER DOOR (DS10LY), REPAIRED BROKEN WIRE IAW ESPM 20-17-10. ALSO FOUND FLOOR TRACK LIGHTING LAMP 1 (DS12LY) SHORTED CAUSING THE OTHER 2 LIGHTS TO BE INOP. REMOVED AND REPLACED FLOOR TRACK LAMP 1 (DS12LY) IAW AMM 33-51-