What was found
[ IN REFERENCE NRC 0070 ] : INITIAL INSPECTION: CORROSION ON INTERCOSTALS IN STA. FS= 349 TO FS= 364 NEAR STGR 27 (2 EA´S) AT MAIN AVIONICS COMPARTMENT. (E/E) [ TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
SUMMARY: NEW INTERCOSTALS IN STA. FS= 349 TO FS= 364 NEAR STGR 27 (2 EA´S) WERE REPLACED PER CRJ900 SRM 51-42-06-001-001-A01.