What was found
EMERGENCY LIGHT ON RT OVERWING PANEL 172CRJ IS INOPERABLE. INVESTIGATED AND FOUND WIRE PULLED OUT OF CONTACT AT LIGHT. INSTALLED SERVICEABLE CONTACT ON WIRE AND CONNECTED TO EMERGENCY LIGHT ON PANEL 172CR, IAW CRJ 900 ESPM 20-26-00. OPERATIONS TEST GOOD, IAW CRJ 900 AMM 33-51-00-710-802-A16.