What was found
LH IB FLAP VANE LEADING EDGE SKIN IS CHAFED AT 3 LOCATIONS WHERE VANE CONTACTS WING TRAILING EDGE STRUCTURE. - REMOVED DAMAGE AREA ON L/H I/B FIXED LEADING EDGE FLAP VANE IAW CRJ 700 SRM 51-12-00-001-001-A01. FOUND TO BE WITHIN LIMITS. RESTORED SURFACE WITH SAME REFERENCE. REPLACED PANEL 584GT IAW SRM 51-40-11-001-001-A01 & 51-25-01-001-001-A01. REFER TO JOB 81005551 OP 77 FOR REPAIR OF PANEL 584HT. WVAC EMP # 56399