What was found
R/H AILERON BUSHING LUGS HAVE DAMAGE ON THE INNER BORE OF THE LUG - COMPLIED WITH REO STEP 1 AND 2 OF REPAIR 6 BORE OVERSIZE OF REO 670-57-61-107 REV B DATED 2019-01-14. PERFORMED LPI ON RH AILERON CENTER HINGE 4 REWORKED BORES IAW BOMBARDIER REO 670-57-61-107 REV B DATED 2019-01-14 STEP 6(3) NO INDICATIONS NOTED AT THIS TIME REF C/O 10055521 JOB 81005551 OP 296 FOR DOCUMENTATION OF WORK PERFORMED. WVAC EMP STAMP # 703 MTC