As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R/H I/B FLAP VANE L/E PANEL 684 FT HAS A ELONGATED HOLE PANEL 684FT OUT OF LIMITS DUE TO DAMAGE NEAR FASTENER HOLE IAW CRJ900 57-52-01-001-A01. LOCATED AND DRILED NEW PANEL IAW CRJ900 SRM 51-40-11 RESTORED FINISH IAW CRJ900 SRM 51-21-11, 51-25-06 AND 51-25-16.