What was found
FRAME AT FS 942 CORRODED BETWEEN STR 25L AND 23R. "REMOVED/LOCATED/DRILLED/DEBURRED/ INSTALLED LOWER SECTION FRAME AT FS 942, 14EA CLEATS,POST SUPPORT,CLAMPS, 2EA DOME NUTPLATES, 2 HYDRO CLAMPS IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001- 51-42-21-001-001-A01, 51-41-02-001-001-A01, AND AMM 20-21-00-910-801-A01.