What was found
F/A WAS UNABLE TO OPEN THE MAIN CABIN DOOR, REQUIRED RAMP EMPLOYEE TO OPEN IT FROM THE OUTSIDE. ADJUSTED DOOR LATCH MECHANISM AND RODS #54 AND #75 IAW AMM 52-11-02. WHILE PERFORMING OPS TEST NOTICED SPIGOT HITTING ON TOP OF DOOR. INSTALLED .024 SHIMS ON BOTH FWD AND AFT SPIGOT IAW AMM 53-21-23. PERFORMED FUNCTIONAL CHECK OF PASSENGER DOOR OPENING AND CLOSING, FORCE WITHIN LIMITS PER AMM 52-11-00. NO OTHER DEFECTS NOTED AT THIS TIME.