What was found
A 1.00 INCH CRACK WAS FOUND IN THE FLOOR BEAM SUPPORT, ADJACENT TO AN EXISTING FASTENER, AT FS 280.00, WL 72.00, LBL 13.50. REPAIRED PER REO 670-53-11-1797.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A 1.00 INCH CRACK WAS FOUND IN THE FLOOR BEAM SUPPORT, ADJACENT TO AN EXISTING FASTENER, AT FS 280.00, WL 72.00, LBL 13.50. REPAIRED PER REO 670-53-11-1797.