What was found
FOUND CORROSION ON RBL 9 FLOOR BEAM FLANGE AT FS 559+64 - FS 559+112 REMOVED CORROSION ON FLOOR BEAM AT RBL9 FROM FS 559+16 TO FS 559+80 REF CRJ 200 SRM 51-21-06. FOUND TO BE OUT OF LIMITS REF CRJ 200 SRM 53-00-00 PGS 101-106 AND CRJ 200 SRM 53-51-43. REPLACED RBL 9 FLOOR BEAM CAP P/N 601R31119-75 FROM FS559+8 TO FS559+120. REF ENDEAVOR AIR EA CRJ253#14468 REV IR DATED 09/03/2022 AND CRJ 200 SRM 51-42-21.