As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAX DOOR FWD STAIR WEB IS CORRODED FOUND FWD STAIR WEB TO BE OUT OF ALLOWABLE LIMITS IAW CRJ 900 SRM 52-11-04-101-001-A01. REMOVED AND INSTALLED SUPPORT ANGLES, DRAG ANGLE AND COUNTERBALANCE SUPPORT MOUNT STRUCTURE IAW CRJ 900 SRM 51-42-06-001-001-A01. LOCATED AND DRILLED NEW SERVICEABLE FWD STAIR WEB IAW CRJ 900 SRM 51-40-11-001-001-A01 REFERENCE JOB 81515751 OP 508 FOR INSTALLATION OF FWD WEB.