What was found
FWD LAV/WASTE DOOR CUTOUT UPPER SILL ANGLE IS CORRODED REMOVED AND INSTALLED NEW SERVICEABLE FWD LAV/WASTE DOOR CUTOUT UPPER SILL ANGLE IAW CRJ-900 SRM 51-42-06-001-001-A01 P/N SH670-32285-15
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD LAV/WASTE DOOR CUTOUT UPPER SILL ANGLE IS CORRODED REMOVED AND INSTALLED NEW SERVICEABLE FWD LAV/WASTE DOOR CUTOUT UPPER SILL ANGLE IAW CRJ-900 SRM 51-42-06-001-001-A01 P/N SH670-32285-15