What was found
"R/H FWD OVERWING EMERGENCY EXIT DOOR S/N SB1426 TOP FORMER IS CRACKED. REPAIRED RH FWD EMERGENCY EXIT DOOR IAW ENDEAVOR EA CRJ952-16667 REV IR DATED 5/31/24. REQUIRES NDT STEP 3 IAW CRJ900, EA NO: CRJ952-16665, REV IR. CONDUCTED AN EDDY CURRENT INSPECTION ON R/H AFT EMERGENCY EXIT DOOR UPPER FORMER CUT LINE EDGES IAW ENDEAVOR AIR EA CRJ952-16665 REV IR(P1) DATED 5/21/2024 STEP 3. TWO INDICATIONS NOTED DURING INSPECTION, EXCEEDING 100% FSH. FAILED NDT. NO OTHER INDICATIONS NOTED AT THIS TIME. BOTH INDICATIONS ARE APPROX. .25"" IN LENGTH PROPAGATING OUT OF CUTLINE EDGES. INDICATIONS ARE MARKED ON THE PART. REQUIRES NDT STEP 3 IAW CRJ900, EA NO: CRJ952-16667, REV IR. CORRECTION TO LINE 2A CORRECTIVE ACTION: CONDUCTED AN EDDY CURRENT INSPECTION ON R/H FWD EMERGENCY EXIT DOOR UPPER FORMER CUTLINE EDGES IAW ENDEAVOR AIR EA CRJ952-16667 REV IR(P1) DATED 5/21/2024 STEP 3. TWO INDICATIONS NOTED DURING INSPECTION, EXCEEDING 100% FSH. FAILED NDT. NO OTHER INDICATIONS NOTED AT THIS TIME. BOTH INDICATIONS ARE APPROX. .25"" IN LENGTH PROPAGATING OUT OF CUTLINE EDGES. INDICATIONS ARE MARKED ON THE PART. REQUIRES NDT STEP 3 IAW CRJ900, EA NO: CRJ952-16667, REV IR. PERFORMED HFEC OF RH FWD EMERGENCY EXIT DOOR CUTLINE EDGE IAW ENDEAVOR AIR EA CRJ952-16667 REV IR(P1) DATED 5/21/24 STEP 3. NO INDICATIONS NOTED AT THIS TIME. PERFORMED HFEC OF RH FWD EMERGENCY EXIT DOOR FABRICATED PARTS IAW ENDEAVOR AIR EA CRJ952-16667 REV IR(P1) DATED 5/21/24 STEP 8. NO INDICATIONS NOTED AT THIS TIME."