What was found
STRINGER SPLICE FROM STR 23R AND FS 333 IS CORRODED. STRINGER 23R SPLICE AT F.S. 333 IS IDENTIFIED AS P/N SH670-32429-4 AND IS CORRODED ACROSS ENTIRE LENGTH. NO ALLOWABLE DAMAGE LIMITS PROVIDED IN CR- J-900 SRM. PART REQUIRES REPLACE. REMOVED STRINGER SPLICE FROM STR 23R AT F.S.333 P/N: SH670-32429-4 IAW CRJ900 SRM 51-42-06-001- 001-A01. LOCATED AND DRILLED STRINGER SPLICE P/N SH670-32429-4S IAW CRJ-900 SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE STGR SPLICE FROM STGR 23R AND FS 333.00. IAW CRJ900 SRM 51-42-06-001-001-A01. INSTALLED STGR CLEAT FROM STGR 23 R, FS 333.00. IAW CRJ900 SRM 51-42-06-001-001-A01. RESTORED FINISH OF THE REWORKED AREA. IAW CRJ900 SRM 51-21-16-001-001-A01. FOR APPLY CIC REFERENCE TO MWC HR00461541.