What was found
DURING INSP. FOUND ALL FOUR OVERWING EMER EXITS/ FORWARD FLOOR EMER EXITS AND MID CABIN FORWARD EMERGENCY LIGHTS INOP. TROUBLESHOT AND FOUND EMERGENCY BATTERY PS37 INCORRECTLY INSTALLED. R/R PS37 BATTERY AND WAS ABLE TO GET ONE O/W EXIT LIGHT WORKING AND BOTH FWD FLOOR EMER EXIT ROW LIGHTS WORKING. BOTH O/W RH EXIT LIGHTS AND FWD MID CABIN LIGHT STILL INOP. R/R PS35, PS36, PS38 BATTERYS IAW JOBCARDS 33-900-701. BOTH RH O/W AND FWD MID CABIN STILL INOP. R/R PS37 BATTERY CHARGER IAW AMM 33-51-17. R/R FWD LH O/W LIGHT BULB IAW AMM 33-51-15. OPS. CHECKS GOOD.