What was found
PASSENGER DOOR FLOOR SILL IS CORRODED BETWEEN F.S.310-349. REMOVED CORRODED FLOOR SILL KICKPLATE ANGLE P/N SH670-31875-7 AND CAP ANGLE P/N SH670-31821-5, INSTALLED NEW SERVICABLE ANGLES IAW CRJ 900 SRM 51-42-06-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER DOOR FLOOR SILL IS CORRODED BETWEEN F.S.310-349. REMOVED CORRODED FLOOR SILL KICKPLATE ANGLE P/N SH670-31875-7 AND CAP ANGLE P/N SH670-31821-5, INSTALLED NEW SERVICABLE ANGLES IAW CRJ 900 SRM 51-42-06-001-001-A01.