What was found
WHILE PERFORMING SB 670BA-53-044 REV G PART B & C - PRIMARY STRUCTURE FS 144 TO FS 280 - REINFORCEMENT OF THE LH & RH SIDES OF THE FS 202.75 BULKHEAD ABOVE THE FLOOR AND NLG BOX WE FOUND THE R/H STRINGER 12A FITTING CC670-33562-001SB WILL ONLY PICK UP TWO FASTENERS ON THE FS 202 BULKHEAD FLANGE IN LIEU OF THREE PER THE SB REQUIREMENTS. ENGINEERING REQUIRED. COMPLIED WITH MHIRJ REO 690-53-11-1684 REV-- DATED 2024-02-09