What was found
PAX DOOR INTERCOSTAL BETWEEN F.S. 319 TO F.S. 333 IS CORRODED. DISPLACED WIRE BUNDLE AT F.S. 310 BETWEEN 19L AND 18L FOR ACCESS TO CORRODED AREA IAW CRJ-700 SRM 51-41-02-001-001-A01. DISPLACED 10EA GROUND WIRES (#1,GS443, GS1839,GS1841,#2,GS329,GS319,GS317,#3,#4) AT FS310-FS333 STGR 21L INTERCOSTAL (BACK UP SILL) FOR ACCESS IAW CRJ 700 SRM 51-41-02-001-001-A01. DISPLACED AVI COMPUTER RACK FROM FS.295-FS.333 IAW CRJ-700 SRM 51-42-06-001-001-A01 REMOVED UNSERVICEABLE INTERCOSTAL BACK UP SILL (P/N:SH670-31822-1) AT FS310-FS333 STGR-21L IAW CRJ-900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 LOCATED AND DRILLED NEW SERVICEABLE BACK UP SILL (P/N SH670-31822-1) ON STRINGER 21L BTW FS 310 TO FS 333. IAW CRJ-700 SRM 51-40-11-001-001-A01 INSTALLED NEW SERVICEABLE BACK UP SILL P/N SH670-31822-1S AT STGR 21L FROM F.S. 310 - F.S. 333 IAW CRJ-700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. INSTALLED CAT TRACK AT 1 EA. LOCATION ON BACK UP SILL P/N SH670-31822-1S IAW CRJ-700 SRM 51-22-00-001-001-A01. INSTALLED AVI COMPUTER RACK FROM FS.295-FS.333 IAW CRJ700 SRM 51-42-06-001-001-A01. APPLIED EDGE SEALANT AND FINISH IAW CRJ700 SRM 51-25-16-001-001-A01 AND 51-23-00-001-001-A01.