What was found
STRINGER 25R IS CORRODED BETWEEN FS 295.00 AND 310.00 REMOVED CORROSION FROM STR 25R BETWEEN 295 & FS 310 IAW CRJ700 SRM 51-- 21-06-001-001-A01. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM TASK 53-21-- 03-101-002-A01. FOUND DAMAGE TO BE OUT OF LIMITS. R & R STRINGER 25R IAW CRJ-700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. LOCATED & DRILLED NEW SERVICEABLE STRINGER 25R P/N SH670-31212-2 AT F.S. 280 - F.S. 333 IAW CRJ--700 SRM 51-40-11-001-001-A01. REMOVED AND REINSTALLED STRINGER SPLICE AT STGR 25R F.S. 333 IAW CRJ-700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. APPLIED EDGE SEALANT AND EXTERIOR/INTERIOR PAINT IAW CRJ-700 SRM51-23-00-001--001-A01 AND 51-25-16-001-001-A01.