What was found
STGR 19R IS CORRODED BETWEEN F.S. 565 TO F.S. 581. BLENDED CORROSION IAW SRM 53-31-03-101-004-A04. PERFORMED LPI ON REWORKED AREAS ON S19R BETWEEN BS 565 AND 581 IAW NDTM PT 1 51-20-008-230-A01. NO INDICATIONS NOTED. PERFORMED UT THICKNESS ON REWORKED AREAS ON S19R BETWEEN BS 565 - 581 IAW NDTM PT 1 51-20-004-270-A01. FOUND LOWEST REMAINING THICKNESS TO BE .035 OR GREATER. INVESTIGATION FOUND PART TO HAVE A MAXIMUM THICKNESS OF .063, BLENDING REMOVED .028, MRT OF .035. PART FOUND TO BE OUT OF LIMITS IAW SRM 53-31-03-101-004-A01. PART REQUIRES REPLACEMENT. CUT AWAY DAMAGED SECTION OF S19R IAW SRM 53-00-03-201-001-A01, STEPS 5A(1-2) IAW SRM 51-21-06-001-001-A01. PERFORMED HFEC OF STRINGER 19R BS 565-581 CUTLINE EDGES IAW NDTM PART 1 51-20-006-250-A01. NO INDICATIONS NOTED. ATTACHED 908.1 IAW TS#012308T. FABRICATED, LOCATED & DRILLED STRINGER AND REPAIR SPLICES IAW SRM 53-00-03-201-001-A01, STEPS 5A(6-13)