As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
"ON THE RH AILERON, FOUND BOTH CENTER UPPER LUG BORE DIAMETERS TO BE OUT OF LIMITS. IB LUG IS .986"" AND OB LUG IS .985"", NOMINAL LIMIT IS .975 +- .0005 REPAIRED OVERSIZED BORES AND PITTING CORROSION TO THE AILERON ACTUATOR CENTER HINGE FITTING LUGS AT AIL STA 338.424 AND 342.123 RHS IAW MHIRJ REO 690-57-61-417 REV -- DATED 2025-08-21. AILERON P/N 601R13400-2 S/N SB0052. "